- Output power: 60W
- Standard reduction ratio: 5~100 ratio.
- Power input voltage: single-phase AC100~120V, single-phase AC200~240V, three-phase AC200~240V
- Speed control range: 80~4500rpm/min.
- Protection functions: overload, overcurrent, overspeed, motor rotation, detector abnormality and other protections.
Specifications
Motor model | Round shaft type | 8BU060A-A30 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pinion type | 8BU060GB-A30 | |||||||||
Driver model | BUD060-A | BUD060-C | ||||||||
Rated output | (W) | 60 | ||||||||
Power input | Rated voltage | (V) | Single phase 110V | Single phase 220V/ Three phase 220V | ||||||
Voltage tolerance | -15% ~ +15% | |||||||||
Frequency | (Hz) | 50/60 | ||||||||
Frequency allowable error | - 5% ~ +5% | |||||||||
Rated input current A | (A) | 1.7 | 1.0/ 0.52 | |||||||
Maximum input current A | (A) | 3.3 | 1.9/ 1.1 | |||||||
Rated RPM | (r/min) | 3000 | ||||||||
Speed control range | (r/min) | 80~4500 | ||||||||
Speed change rate | - 0.2% ~ +0.2% | |||||||||
Rated torque | (N-m) | 0.19 | ||||||||
Maximum torque | (N-m) | 0.29 | ||||||||
Rate Time | Continuous | |||||||||
Degree of Protection | Motor: IP40 Driver: IP20 | |||||||||
Insulation class | Class B | |||||||||
Shaft material | Motor shaft, reducer output shaft: steel | |||||||||
Driver detector | Hall element | |||||||||
Insulation current protection | Motor: Coil to case DC500V 100MΩ or more Driver: Power terminal to driver heat sink DC500V 100MΩ or more |
|||||||||
Insulation pressure resistance | Motor: coil to housing AC1500V/1 minute Driver: Power terminal to driver shell AC500V/1 minute |
|||||||||
Usage environment | Temperature: 0 ~ +40℃ (no freezing) Humidity: below 85% (no condensation) Altitude: below 1000m above sea level Environment: No corrosive gas or dust. Do not use in explosive, radioactive places, magnetic fields, vacuum and other special environments. |
|||||||||
Storage environment | Temperature: -20 ~ +70℃ (no freezing) Humidity: below 85% (no condensation) Altitude: below 3000m above sea level Environment: Avoid direct sunlight, less salt and well-ventilated place. |
Product model list
Motor model | Type | Frame number | Output power | Motor shaft type | Driver model | Power supply voltage | Corresponding gearbox | Reduction ratio |
---|---|---|---|---|---|---|---|---|
8BU060A-A30 | Brushless motor | 80mm | 60W | Round shaft | BUD060-A | Single phaseAC100~120V | - | - |
BUD060-C | Single phaseAC200~240V/ Three-phaseAC200~240V | |||||||
8BU060GB-A30 | Brushless motor | 80mm | 60W | Helical gear shaft | BUD060-A | Single-phaseAC100~120V | 8GB | 5,10,15,20,30,50,100 |
BUD060-C | Single-phaseAC200~240V/ Three-phaseAC200~240V |
Motor torque characteristics
Reducer specifications
Reducer | Deceleration ratio | 5 | 10 | 15 | 20 | 30 | 50 | 100 | ||
---|---|---|---|---|---|---|---|---|---|---|
Motor shaft speed | ||||||||||
Output shaft speed | (r/min) | 3000r/min | 600 | 300 | 200 | 150 | 100 | 60 | 30 | |
Allowable torque | (N.m) | 60W | 80~3000r/min | 0.83 | 1.65 | 2.25 | 3.30 | 4.75 | 7.95 | 16.00 |
4500r/min | 0.59 | 1.17 | 1.17 | 2.34 | 3.33 | 5.58 | 11.16 | |||
Allowable hoisting load | (N) | 60W | Distance from the front of the output shaft 10mm | 200 | 300 | 450 | ||||
60W | Distance from the front of the output shaft 20mm | 250 | 350 | 550 | ||||||
Allowable thrust load | (N) | 60W | 100 | |||||||
Operation direction | In the same direction as the motor | In the opposite direction of the motor |
scrollable
External View
Unit:mm
Ratio | L |
---|---|
5~20 | 85mm |
30~100 | 90mm |
Operation Instructions
■ Driver Functions
- Main power connector
- Single-phase input: Please connect L1 and L2 to the main power connector.
- Three-phase input: Please connect L1, L2, L3 to the main power connector.
■ Functions
Functions | content | |
---|---|---|
Operation Mode | Motor start/stop | |
Switch running direction | ||
Adjusting speed | ||
Selection of three operating modes | ||
Four-stage operating setting (speed, torque limit, acceleration/deceleration time) | ||
Upper and lower limit settings of motor speed | ||
Set and display the speed reduction ratio or increase ratio | ||
Gentle start/soft stop | ||
Simple stop and hold mode | ||
Speed setting method | Use the knob to adjust the speed | |
Use I/O to set the speed of four-stage running data | ||
Acceleration time, deceleration time* |
Analog Setting: Set by acceleration and deceleration knob. Set within the range of 0.1~15 seconds. | |
Digital Setting: Set the number of each segment of the operating data. Set within the range of 0.1~15 seconds. | ||
*1 Actual acceleration time and deceleration time are affected by the customer's usage conditions, load inertia, load torque, etc. | ||
Input signal | Optocoupler input method: power supply must be less than 10mA | |
Operation using internal power supply: DC5V | ||
Connectable external DC power supply: DC5~30V | ||
SINK input/SOURCE input | ||
Three groups of inputs (X0~X2) can be assigned to signals. Factory settings: [FWD], [REV], [M0] | ||
Output signal | Optocoupler, transistor open collector circuit output | |
External DC power supply: DC5~30V | ||
SINK output/SOURCE output | ||
Two sets of outputs (Y0~Y1) can be assigned to the signal. Factory setting: [SPEED OUT], [ALARM OUT] | ||
Protection function | Abnormal alarm display, overload, overcurrent, overvoltage, undervoltage, overspeed, motor stall, detector abnormality, safe start, driver overtemperature, driver power module abnormality. |
■ Multi-stage speed operation
While using multi-stage speed, switch between M0, M1 and input to perform multi-stage operation.
Example:
Operation data | M0 | M1 | Speed |
---|---|---|---|
No.1 | OFF | OFF | 3000 |
No.2 | ON | OFF | 2000 |
No.3 | OFF | ON | 1000 |
No.4 | ON | ON | 500 |